All distributed Natus neoBLUE 2 systems with LED PCB replacements received after February 16, 2012. For use only with neoBLUE devices manufactured between 2002 and 2007 (neoBLUE2)
ACCU-CHEK Tender II 13/80 10 + 10 pieces || Product Usage: || Intended for the infusion and/or injection of fluids into the body below the surface of the skin. The indwelling catheter can be inserted independently from the infusion catheter and can be accessed for the injections through the injection port. The indwelling catheter can also be securely attached to the infusion catheter by means of a proprietary click-lock connector for the infusion of drugs subcutaneously. The infusion set can be detached from the indwelling catheter, and the catheter capped to allow freedom from the infusion set and pump for showers, athletics or other activities.
ACCU-CHEK Tender II 13/110 10 + 10 pieces || Product Usage: || Intended for the infusion and/or injection of fluids into the body below the surface of the skin. The indwelling catheter can be inserted independently from the infusion catheter and can be accessed for the injections through the injection port. The indwelling catheter can also be securely attached to the infusion catheter by means of a proprietary click-lock connector for the infusion of drugs subcutaneously. The infusion set can be detached from the indwelling catheter, and the catheter capped to allow freedom from the infusion set and pump for showers, athletics or other activities.
ACCU-CHEK Tender II 17/60 10 + 10 pieces || Product Usage: || Intended for the infusion and/or injection of fluids into the body below the surface of the skin. The indwelling catheter can be inserted independently from the infusion catheter and can be accessed for the injections through the injection port. The indwelling catheter can also be securely attached to the infusion catheter by means of a proprietary click-lock connector for the infusion of drugs subcutaneously. The infusion set can be detached from the indwelling catheter, and the catheter capped to allow freedom from the infusion set and pump for showers, athletics or other activities.
ACCU-CHEK Tender II 17/80 10 + 10 pieces || Product Usage: || Intended for the infusion and/or injection of fluids into the body below the surface of the skin. The indwelling catheter can be inserted independently from the infusion catheter and can be accessed for the injections through the injection port. The indwelling catheter can also be securely attached to the infusion catheter by means of a proprietary click-lock connector for the infusion of drugs subcutaneously. The infusion set can be detached from the indwelling catheter, and the catheter capped to allow freedom from the infusion set and pump for showers, athletics or other activities.
ACCU-CHEK Tender II 17/110 10 + 10 pieces || Product Usage: || Intended for the infusion and/or injection of fluids into the body below the surface of the skin. The indwelling catheter can be inserted independently from the infusion catheter and can be accessed for the injections through the injection port. The indwelling catheter can also be securely attached to the infusion catheter by means of a proprietary click-lock connector for the infusion of drugs subcutaneously. The infusion set can be detached from the indwelling catheter, and the catheter capped to allow freedom from the infusion set and pump for showers, athletics or other activities.
Distributed US (nationwide) and the country of Canada.
Description du dispositif
GETINGE 46-SERIES Medical Washer-Disinfector, Models 46-4 and 46-5, with PACS 300/350 Control Series with dryer --- Class II, exempt from 510(k) requirements. || For use in healthcare facilities and laboratories where reusable items such as instruments, utensils, anesthesia sets, and glassware are handled for decontamination purposes.
Lite DM (Lite Data Manager) || Software Version(s): Versions 2.0.0.19 and lower || Product Model #: D00A00224D || The Lite DM (Lite Data Manager) is a software application developed by HORIBA || Medical intended to receive, store, and manage Startup, Patient, and Quality Control || (QC) results from an ABX Micros 60 Hematology Analyzer or ABX Micros CRP 200 || Hematology Analyzer. Only one instrument connection is allowed per each Lite DM || workstation. The Lite DM application runs on a PC within a Windows Operating || System platform. Data transmitted from the instrument to the Lite DM workstation is a Serial RS-232 unidirectional ABX Format communication. The Lite DM can act as a standalone data manager for data received from the instrument, or allow transmission of this data to a Host (LIS Laboratory Information System or EMR Electronic Medical Record system). || Following the completion of each blood sample analysis performed on the connected HORIBA Medical hematology analyzer, results are then communicated (uni-directional) to the Lite DM workstation. Results received will display to the user in a specific color coding format indicating any normal or panic reference range violations. Results are then rejected or accepted by the user for final reporting - formatted to guidelines stipulated by CLIA. At no time are any results interpreted; only reported for review and appropriate action.
Worldwide Distribution - US Distribution to the states of UT, TX, and IL, and to the countries Austria, Germany, Spain, Switzerland, and Netherlands. No VA/military/govt consignees.
Description du dispositif
Self-Righting Luer Lock Tip Cap, Green and Self-Righting Luer Slip Tip Cap, Yellow, Baxter Healthcare Corporation, 14445 Grasslands Dr. Englewood, CO 80112 USA. DISCPAC Syringe Tip Caps. RER H93866100 x 1000. Sterile
The affected product was distributed to the following states: OH, MA, HI, NJ, TN, TX, MO, and GA. The affected product was distributed to the following foreign countries: Canada, Germany and Venezuela.
Description du dispositif
Ferno Model 35X PROFlexx Stretchers, one unit per package
Worldwide Distribution - US Distribution to the states of : AZ, MO, PA and WI., and the countries of : Austria, India and Japan.
Description du dispositif
Civco, MTSR02 Shoulder Retractor with Sherpa Wrist Loops Kit with Base, Non-sterile re-usable wool wrist strap, REF: 20SR02SUB2, Rx Only, || The devise is intended to pull patients shoulders down for clearance when treating lateral fields to the neck.
Multi-Lumen PI CVC Kit and PSI Kit: 3-L 7 FR X 8 product code: ASK-45703-POSU lot #23F13L0166, exp. 31-Jul-2015: || Product Usage: || Multi-Lumen PI CVC Kit: An intravascular catheter is a device that consists of a slender tube and any necessary connecting fittings and that is inserted into the patients vascular system for short term use (less than 30 days) to sample blood, monitor blood pressure, or administer fluids intravenously. The device may be constructed of metal, rubber, plastic, or a combination of these materials. PSI Kit: A catheter introducer is a sheath used to facilitate placing a catheter through the skin into a vein or artery.
Worldwide Distribution - US Distribution to the states of : AZ, MO, PA and WI., and the countries of : Austria, India and Japan.
Description du dispositif
Civco, MTSR03 Shoulder Retractor with Wrist Loops Kit with Base, plus two pairs of wrist loops (nylon and sherpa), Non-sterile re-usable wool wrist strap, REF: 20SR03, Rx || The devise is intended to pull patients shoulders down for clearance when treating lateral fields to the neck.
BD 10 mL Syringe BD Luer-Lok Tip with Blunt Plastic Cannula, Not for Skin Injection ; Catalog #303348, || BD 10 mL Syringe Luer-Lok Tip with Blunt Fill Needle 18G x 1 1/2 (1.2mm x 40 mm), not for skin injection; Catalog #305064 || BD 10 mL Syringe Luer-Lok Tip with BD Precision Glide Needle 20G x 1 (0.9mm x 25mm); Catalog #305064 || Product Usage: || 1) BD Blunt Plastic Cannula is used to penetrate pre-slit septums covering injection sites, as well as vials designed for penetration with needless IV access cannula. || 2) The blunt steel canula will be targeted for exiting applications of pointer cannula, where blunt steel cannula would provide increased safety. Such existing applications include: || -Accessing pre-slit/pre-pierced IV septum ports || -Providing for fluid transfer || -Can be used as tubing adapter || 3) The BD single use Hypodermic Syringe is intended for use by healthcare professional for general purpose fluid aspiration/injection.