This equipment is an argon gas administration system that is used in conjunction with an electrosurgical generator for the effects of argon gas assisted electrosurgery. The system offers precise energy application for non-contact coagulation on large surface areas. The coagulation intensified by argon, hemostatic hemostasis with a thinner and more flexible eschar, less possible bleeding and less tissue damage.
The reusable staplers have applications in abdominal, gynecology, pediatric and thoracic surgery for resection, cross-sectional and anastomosis creation. They can be used for transverse cutting and resection of the pancreas. The recharge of a solouso has applications in abdominal, gynecological, pediatric and thoracic surgical procedures for resection, transection and the creation of anastomosis. They can be used for transection and resection of the pancreas.
The TRELLIS peripheral infusion system is designed for the controlled and selective infusion of liquids, includingtrolyolitics, inside the peripheral vasculature.
Primary dressing for slow drainage wounds such as surgical sites, skin tears or poorly draining wounds. Indicated to cover a wound, give or withstand a moist wound environment, and allow the exchange of gases such as oxygen and water vapor to through the device. Surgical incisions, lacerations, central and peripheral line sites, pressure ulcers, stasis ulcers, arterial ulcers, diabetic ulcers, abrasions and donor areas. Lacerations or eye injuries. Used to absorb fluids and secretions in procedures such as postalaparotomy, tumors, infected wounds, chronic wounds, wounds with high exudate and premature rupture of membranes, among others. Primary dressing in arms and legs, secondary dressing in abdomen.
It includes a hand-operated thermometer with a battery attached to a base station. It measures the temperature by feeling the infrared emissions in the tympanic membrane at the ear canal. Oral, rectal, central and axillary temperatures are measured based on the tympanic reading. Indicated for use in patients in intensive care and for measurements of temperature in the membranatympanic.
The 640G DE MINIMED system is indicated for the continuous administration of insulin, at fixed and variable rates, for the treatment of diabetes mellitus in people who need insulin. In addition, the system is indicated to perform a continuous or periodic control of glucose levels in the fluid under the skin, as well as to detect possible episodes of high and low glucose. When a sensor and a transmitter are used, the pump displays continuous glucose values from the sensor and stores these data so that they can be analyzed in order to track the patterns and improve the treatment of diabetes. These data can be downloaded to a PC to analyze the historical glucose values. The continuous glucose sensor values provided by the 640G DE MINIMED system should not be used directly to make adjustments in therapy, but rather provide an indication that confirmation may be necessary. by digital puncture. All therapy settings should be based on the measurements obtained with a blood glucose monitor and not with the value shown by the pump.
The 640G DE MINIMED system is indicated for the continuous administration of insulin, at fixed and variable rates, for the treatment of diabetes mellitus in people who need insulin. In addition, the system is indicated to perform a continuous or periodic control of glucose levels in the fluid under the skin, as well as to detect possible episodes of high and low glucose. When a sensor and a transmitter are used, the pump displays continuous glucose values from the sensor and stores these data so that they can be analyzed in order to track the patterns and improve the treatment of diabetes. These data can be downloaded to a PC to analyze the historical glucose values. The continuous glucose sensor values provided by the 640G DE MINIMED system should not be used directly to make adjustments in therapy, but rather provide an indication that confirmation may be necessary. by digital puncture. All therapy settings should be based on the measurements obtained with a blood glucose monitor and not with the value shown by the pump.
The MEDTRONIC model 6416 temporary transvenous stimulation cable system has a bipolar active fixation cable and a lubri- cated lubricant guide catheter. This system has been designed for temporary intracardiac stimulation and the recording of electrocardiograms. It is a disposable system, for temporary use with only one patient, with an estimated implant duration of 7 days or less.