1104BC Combo Kit including 1 Cranial Kit w/Cam Chuck, 1 OLM Intracranial Pressure Monitoring Kit, contains sterile and non-sterile product. Integra NeuroSciences, Integra LifeSciences 3498 West 2400 South, West Valley City, Utah 84119. || Product Usage: The Xylocaine component of the kit is used as an injectable local anesthetic during cranial access operations.
Worldwide Distribution - US Nationwide in the states of: MA, NY and countries of : Algeria, Australia, Austria, Bahrain, Belgium, British Virgin Islands, Bulgaria, Canada, Denmark, Egypt, Estonia, Finland, France, Georgia, Germany, Greece, Hong Kong, India, Iran, Iraq, Ireland, Israel, Italy, Japan, Jordan, Korea, Kuwait, Libya, Lithuania, Macedonia, Malaysia, Malta, Mexico, Nigeria, Norway, Pakistan, Peru, Poland, Romania, Serbia, Singapore, Slovakia, South Africa, Spain, Sri Lanka, Sweden, Taiwan, Thailand, Tunisia, Turkey, UAE, Ukraine, United Kingdom, and Vietnam,
Description du dispositif
Integra 3; Model Numbers: 6-54-100, 6-54-110, 6-54-150, 6-54-160 || Product Usage: || The Rl TDU500 Micromanipulator for Assisted Reproduction is used to accurately position microtools under a microscope for the techniques of Assisted Reproduction. The Rl Integra is a configuration comprising two TDU500 micromanipulators, two air syringes and temperature control system within a single housing.
Integra Meshed Dermal Regeneration Template 5 cmx 5 cm (2 in x 2in) Rx Only || Meshed Integra¿ Dermal Regeneration Template, (Integra template) is a bilayer membrane system for skin replacement. The dermal replacement layer is made of a porous matrix of fibers of cross-linked bovine tendon collagen and glycosaminoglycan (chondroitin-6-sulfate) that is manufactured with a controlled porosity and defined degradation rate. The epidermal substitute layer is made of a thin polysiloxane (silicone) layer to control moisture loss from the wound. Integra template is indicated for the postexcisional treatment of life-threatening full-thickness or deep partial-thickness thermal injuries where sufficient autograft is not available at the time of excision or not desirable due to the physiological condition of the patient. Integra template is also indicated for the repair of scar contractures when other therapies have failed or when donor sites for repair are not sufficient or desirable due to the physiological condition of the patient || Manufactured by: || Integra LifeSciences Corporation || 311 Enterprise Drive, Plainsboro, NJ 08536 || 877-444-1122 USA n 609-936-5400 outside USA || 866-800-7742 fax