Rappel de MAQUET HLS and PLS Sets with BIOLINE Coating (extracorporeal support sets)BE-HLS 5050 HLS Set Advanced 5.0

Selon Department of Health, Therapeutic Goods Administration, ce/cet/cette rappel concerne un dispositif en/au/aux/à Australia qui a été fabriqué par Maquet Australia Pty Ltd.

Qu'est-ce que c'est?

Une correction ou un retrait opéré par un fabricant afin de répondre à un problème causé par un dispositif médical. Les rappels surviennent lorsqu'un dispositif médical est défectueux, lorsqu'il pourrait poser un risque pour la santé, ou les deux à la fois.

En savoir plus sur les données ici
  • Type d'événement
    Recall
  • ID de l'événement
    RC-2016-RN-01514-1
  • Classe de risque de l'événement
    Class I
  • Date de mise en oeuvre de l'événement
    2016-11-17
  • Pays de l'événement
  • Source de l'événement
    DHTGA
  • URL de la source de l'événement
  • Notes / Alertes
    Australian data is current through July 2018. All of the data comes from the Australian Therapeutic Goods Administration, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Australia.
  • Notes supplémentaires dans les données
  • Cause
    In january 2015 maquet cardiopulmonary noticed an increase in the frequency of complaints for the hls and pls sets regarding blood leaking from the gas outlet connector. in the defective products between 6-14 fibers have separated from the polyurethane casting (or 'potting'), which is at the ends of the fibers. this separation allows patient blood to leak out of the system (via the gas outlet connector). a safety alert was issued to alert customers regarding this issue at the time.Since the release of safety alert, maquet has identified the root cause and have implemented and validated the necessary corrections that return the products to their original performance specifications. due to the risks associated with the use of the oxygenators with increased leakage, maquet is now initiating a recall of the potentially affected lot numbers.
  • Action
    Customers are advised to quarantine affected products in their inventory and return them to Maquet. A credit will be issued upon receipt of the returned products.

Device

  • Modèle / numéro de série
    MAQUET HLS and PLS Sets with BIOLINE Coating (extracorporeal support sets)BE-HLS 5050 HLS Set Advanced 5.0 Product Order Number: 70104.8127All Lot Numbers below 70104520BE-HLS 7050 HLS Set Advanced 7.0 Product Order Number: 70104.7753All Lot Numbers below 70100115BE-PLS 2050 PLS SetProduct Order Number: 70102.7818All Lot Numbers below 70104119BE-PLS 2051 PLS Set PlusProduct Order Number: 70105.0310All Lot Numbers below 70102843ARTG Numbers: 193475, 192105
  • Manufacturer

Manufacturer

  • Société-mère du fabricant (2017)
  • Source
    DHTGA