Rappel de ARIA PRACTICE MANAGEMENT - 4D INTEGRATED TREATMENT CONSOLE (4DITC)

Selon Health Canada (via FOI), ce/cet/cette rappel concerne un dispositif en/au/aux/à Canada qui a été fabriqué par VARIAN MEDICAL SYSTEMS INC..

Qu'est-ce que c'est?

Une correction ou un retrait opéré par un fabricant afin de répondre à un problème causé par un dispositif médical. Les rappels surviennent lorsqu'un dispositif médical est défectueux, lorsqu'il pourrait poser un risque pour la santé, ou les deux à la fois.

En savoir plus sur les données ici
  • Type d'événement
    Recall
  • ID de l'événement
    108134
  • Classe de risque de l'événement
    II
  • Date de mise en oeuvre de l'événement
    2012-05-07
  • Pays de l'événement
  • Source de l'événement
    HC
  • Notes / Alertes
    Canadian data is current through March 2018. All of the data comes from Health Canada, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Canada.
  • Notes supplémentaires dans les données
  • Cause
    An anomaly has been identified with 4d integrated treatment console (4ditc) when a physical wedge accessory is prescribed. the 4ditc may erratically fail to load the planned wedge without warning or notification when receiving an approved plan from the oncology information system (ois). after a plan with wedge field has been opened in 4ditc users may not notice that the wedge filter is missing from a selected field. the treatment application will not notify the user of this anomaly and will not prevent beam delivery. the user may become aware that the wedge filter is missing only after the treatment field has been partially or completely delivered and when the user attempts to close the patient from the treatment application. in this situation the treatment application forces the user to unload the patient requires user authorization and informs the user that the treatment record for the missing wedge field will not be saved to the ois. delivery of a treatment field without the planned and calculated wedge filter could result in an over dosage for that beam and potentially an unintended dose uniformity of the target treatment volume.

Device

  • Modèle / numéro de série
    Model Catalog: V8.1.2 (Lot serial: >10 SERIAL NUMBERS.); Model Catalog: V8.6 (Lot serial: >10 SERIAL NUMBERS.); Model Catalog: V8.8 (Lot serial: >10 SERIAL NUMBERS.); Model Catalog: V8.1.2 (Lot serial: CONTACT MANUFACTURER.); Model Catalog: V8.6 (Lot serial: CONTACT MANUFACTURER.); Model Catalog: V8.8 (Lot serial: CONTACT MANUFACTURER.)
  • Description du dispositif
    Aria Practice Management