Rappel de PENTAX DUODENOSCOPE

Selon Health Canada (via FOI), ce/cet/cette rappel concerne un dispositif en/au/aux/à Canada qui a été fabriqué par PENTAX CANADA INC..

Qu'est-ce que c'est?

Une correction ou un retrait opéré par un fabricant afin de répondre à un problème causé par un dispositif médical. Les rappels surviennent lorsqu'un dispositif médical est défectueux, lorsqu'il pourrait poser un risque pour la santé, ou les deux à la fois.

En savoir plus sur les données ici
  • Type d'événement
    Recall
  • ID de l'événement
    30529
  • Classe de risque de l'événement
    II
  • Date de mise en oeuvre de l'événement
    2017-03-14
  • Pays de l'événement
  • Source de l'événement
    HC
  • Notes / Alertes
    Canadian data is current through March 2018. All of the data comes from Health Canada, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Canada.
  • Notes supplémentaires dans les données
  • Cause
    During interactive discussions with us fda concerning a 510(k) additional information ("ai") request for the ed-3490tk duodenoscopes the fda requested that pentax perform a root cause analysis to determine how soiling occurred on the surface of the suction cylinder and under the distal cap during testing. fda also requested that pentax identify risk mitigation strategies to address the manufacturing process possible damage to the duodenoscope with use and any other aspects of risk mitigation. as a result of the communications with fda and at the suggestion of fda it was decided that pentax would issue a customer safety communication to advise customers who use ed-3490tks about a potential issue associated with the distal cap and offer recommendations intended to reduce the potential risk for contamination and subsequent patient infection. specifically the user communication states "during manufacturing of ed-3490tk duodenoscopes silicone adhesive is applied to the distal tip prior to affixing the distal cap. in some instances cracks or gaps may form in the adhesive that may be vulnerable to fluid ingress and soiling." the letter reminds users of the importance of using the ed-3490tk in accordance with its current labeling and assuring that all reprocessing personnel are knowledgeable and thoroughly trained on the current ifu for manual reprocessing of these devices. additionally the letter recommends that users "immediately remove from use any ed-3490tk duodenoscope that shows visible signs of wear or physical damage" and states that pentax will provide on-site inspections to assess duodenoscope functionality with particular attention to the integrity of the distal cap and provide in-house servicing as needed.

Device

  • Modèle / numéro de série
    Model Catalog: ED-3490TK (Lot serial: >10 NUMBERS CONTACT MFG)
  • Description du dispositif
    PENTAX VIDEO DUODENOSCOPE
  • Manufacturer

Manufacturer

  • Adresse du fabricant
    MISSISSAUGA
  • Société-mère du fabricant (2017)
  • Source
    HC