Rappel de V60 VENTILATOR SYMBOLS ONLY WITH CFLEX AND AVAPS OPTIONS

Selon Health Canada (via FOI), ce/cet/cette rappel concerne un dispositif en/au/aux/à Canada qui a été fabriqué par PHILIPS ELECTRONICS LTD..

Qu'est-ce que c'est?

Une correction ou un retrait opéré par un fabricant afin de répondre à un problème causé par un dispositif médical. Les rappels surviennent lorsqu'un dispositif médical est défectueux, lorsqu'il pourrait poser un risque pour la santé, ou les deux à la fois.

En savoir plus sur les données ici
  • Type d'événement
    Recall
  • ID de l'événement
    90376
  • Classe de risque de l'événement
    II
  • Date de mise en oeuvre de l'événement
    2017-02-07
  • Pays de l'événement
  • Source de l'événement
    HC
  • Notes / Alertes
    Canadian data is current through March 2018. All of the data comes from Health Canada, except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Canada.
  • Notes supplémentaires dans les données
  • Cause
    The v60 ventilator with version 2.20 software installed may falsely detect that the blower motor has stalled. if this condition occurs the software will cause the ventilator to shut down (vent inop) and display error code 100e. ventilatory support will cease. an audible high-priority alarm will sound continuously for at least 2 minutes when the v60 shuts down for any vent inop condition and is operating on battery power. if the v60 is connected to ac power (mains supply) the alarm will continue to sound until an operator intervenes. if the v60 is connected to a remote alarm system the alarm system will be activated until action is taken by the operator. error code 100e only exists in v60 version 2.20 software. therefore v60's running version 2.10 software are not subject to this particular vent inop condition. an audible high-priority alarm will sound continuously for at least 2 minutes when the v60 shuts down for any vent inop condition and is operating on battery power. if the v60 is connected to ac power (mains supply) the alarm will continue to sound until an operator intervenes. if the v60 is connected to a remote alarm system the alarm system will be activated until action is taken by the operator. error code 100e only exists in v60 version 2.20 software. therefore v60's running version 2.10 software are not subject to this particular vent inop condition.

Device

  • Modèle / numéro de série
    Model Catalog: 1053614 (Lot serial: ALL)
  • Description du dispositif
    V60 VENTILATOR SYMBOLS ONLY WITH CFLEX AND AVAPS OPTIONS
  • Manufacturer

Manufacturer

  • Adresse du fabricant
    MARKHAM
  • Société-mère du fabricant (2017)
  • Source
    HC