Avis De Sécurité sur cystoscopy bridge

Selon Agency for Medicinal Products and Medical Devices of the Republic of Slovenia (via FOI), ce/cet/cette avis de sécurité concerne un dispositif en/au/aux/à Slovenia qui a été fabriqué par OLYMPUS KEYMED.

Qu'est-ce que c'est?

Les avis de sécurité sont des communications que les fabricants de dispositifs médicaux ou leurs représentants font parvenir en particulier aux travailleurs du secteur médical, mais aussi aux utilisateurs de ces dispositifs. Les avis de sécurité concernent les actions entreprises quant aux dispositifs présents sur le marché et peuvent inclure des rappels et des alertes.

En savoir plus sur les données ici
  • Type d'événement
    Field Safety Notice
  • Date
    2017-09-01
  • Pays de l'événement
  • Source de l'événement
    AMPMDRS
  • Notes / Alertes
    Data from Slovenia is current through February 2019. All of the data comes from the Agency for Medicinal Products and Medical Devices of the Republic of Slovenia (via FOI), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Slovenia.
  • Notes supplémentaires dans les données
  • Cause
    Olympus is implementing a field safety corrective action ("fsca") of the cystoscopy bridges and the working insert referenced above. cystoscopy bridges and working inserts are used for endoscopic diagnosis and treatment in urologic applications. olympus has initiated this fsca after receiving complaints about fragments of adhesive which detached from inside the working channel of the referenced cystoscopy bridge models. cracking, chipping, missing pieces, and delamination of the adhesive have been observed. investigations have confirmed that this adhesive can detach during the intended use of the cystoscopy bridge or working insert, e.G. when inserting an instrument through the working channel. as a result, a fragment of the adhesive may fall inside the patient's bladder or urethra and will need to be retrieved. although typically flushed out with irrigation fluid or passed naturally, the retrieval of large fragments of the adhesive could require additional surgical treatment. furthermore, the procedure can be prolonged resulting in extended anesthesia. .

Device

  • Modèle / numéro de série
    A20975A Working insert, with ramp, one way 13ZW, 149W, 14ZW, 159W, 15ZW, 162W, 168W A20976A Bridge, one way 146W, 147W, 148W, 149W, 14XW, 14YW, 14ZW, 151W, 152W, 153W, 154W, 155W, 156W, 157W, 158W, 159W, 15XW, 15YW, 161W, 162W, 163W, 164W, 165W, 167W, 168W, 16YW, 16ZW, 171W, 172W A20977A Bridge, two way 146W, 148W, 149W, 14XW, 14ZW, 151W, 152W, 153W, 154W, 155W, 156W, 158W, 159W, 15XW, 15YW, 161W, 162W, 163W, 164W, 165W, 166W, 167W, 168W, 169W, 16XW, 16ZW, 171W, 172W, 173W