Avis De Sécurité sur Ebb Complete Tamponade System (CTS-lOOO)

Selon Agency for Medicinal Products and Medical Devices of the Republic of Slovenia (via FOI), ce/cet/cette avis de sécurité concerne un dispositif en/au/aux/à Slovenia qui a été fabriqué par Clinical Innovations LLC .

Qu'est-ce que c'est?

Les avis de sécurité sont des communications que les fabricants de dispositifs médicaux ou leurs représentants font parvenir en particulier aux travailleurs du secteur médical, mais aussi aux utilisateurs de ces dispositifs. Les avis de sécurité concernent les actions entreprises quant aux dispositifs présents sur le marché et peuvent inclure des rappels et des alertes.

En savoir plus sur les données ici
  • Type d'événement
    Field Safety Notice
  • Date
    2015-07-09
  • Pays de l'événement
  • Source de l'événement
    AMPMDRS
  • Notes / Alertes
    Data from Slovenia is current through February 2019. All of the data comes from the Agency for Medicinal Products and Medical Devices of the Republic of Slovenia (via FOI), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Slovenia.
  • Notes supplémentaires dans les données
  • Cause
    This is to inform you of a voluntary global recall of clinical innovations’ ebb complete tamponade system (cts- 1000) involving lot numbers 1214—v-424; 1214-f-403 .The purpose of the recall is to address the potential for a balloon leak which may affect your ability to deliver therapy, when needed. clinical innovations’ records indicate you have received a product that is affected by this action. following a report that an ebb complete tamponade system (cts-looo) had leaked during use, clinical innovations conducted an investigation on the returned device and concluded that the leakage was caused by a failure mode of the bond at distal end of the uterine balloon a balloon leak can be identified by a failure to arrest bleeding, ultrasound revealing loss of balloon volume, or blood-tinged liquid being expelled from the drainage tube. a uterine balloon with a leak may not provide the anticipated tamponade effect, requiring further intervention. although unlikely, death could occur due to the failure mode associated with this recall. in the report received, the patient had stabilized prior to the leak being noticed by the clinical team. because there is a potential for additional interventions with a balloon leak (such as arterial embolization or surgery) required to control a postpartum hemorrhage, we are requesting that you return all unused ebb complete tamponade system (cts-looo) from the above—listed lot numbers. no other clinical innovations products are affected by this issue.