Avis De Sécurité sur ONLINE TDM Gentamicin assay

Selon Agency for Medicinal Products and Medical Devices of the Republic of Slovenia (via FOI), ce/cet/cette avis de sécurité concerne un dispositif en/au/aux/à Slovenia qui a été fabriqué par Roche Diagnostics.

Qu'est-ce que c'est?

Les avis de sécurité sont des communications que les fabricants de dispositifs médicaux ou leurs représentants font parvenir en particulier aux travailleurs du secteur médical, mais aussi aux utilisateurs de ces dispositifs. Les avis de sécurité concernent les actions entreprises quant aux dispositifs présents sur le marché et peuvent inclure des rappels et des alertes.

En savoir plus sur les données ici
  • Type d'événement
    Field Safety Notice
  • Pays de l'événement
  • Source de l'événement
    AMPMDRS
  • Notes / Alertes
    Data from Slovenia is current through February 2019. All of the data comes from the Agency for Medicinal Products and Medical Devices of the Republic of Slovenia (via FOI), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of recall data from the U.S. and Slovenia.
  • Notes supplémentaires dans les données
  • Cause
    In the last version of this customer letter we informed you about the implementation of an instrument factor (if) for online tdm gentamicin that was - based on available data - the mitigation for the reported issue. however, against initial data the correction of the instrument factor did not mitigate the issue. we received complaints from customers who implemented the if, observing decreased sample recovery using the online tdm gentamicin assay. since availability of fresh patient samples for gentamicin is very limited, frozen patient samples had to be used for internal investigations. obviously, the internal results obtained with these samples and used for the implementation of the if did not match with the external observations reported by customers. further investigations were initiated at roche to understand this mismatch. in order to verify the internal results a new panel of patient samples was collected (panel b, stored at -80°c) and compared to the panel that was used for the determination of the if (panel a, stored at -20°c). .

Device

  • Modèle / numéro de série
    04490843190 ONLINE TDM Gentamicin 100 Tests c 311, c 501/502 05841291190 ONLINE TDM Gentamicin 100 Tests c 701/702
  • Manufacturer

Manufacturer