Infusion pumps

Fabricant

268 dispositifs médicaux avec un nom similaire

En savoir plus sur les données ici

  • Modèle / numéro de série
    Not available
  • Classification du dispositif
  • Classe de dispositif
    3
  • Dispositif implanté ?
    No
  • Distribution
    Worldwide Distribution - USA (nationwide) the countries of: AE, AR, AT, AU, BA, BH, BM, BR, BS, CA, CH, CL, CN, CO, CR, CY, CZ, DE, DK, DO, DZ, EC, EE, EG, ES, FI, FR, GB, GR, GT, HK, HR, HU, IE, IL, IN, IQ, IT, JO, JP, KR, KW, LB, LC, LV, MK, MX, MY, NL, NO, NZ, OM, PA, PE, PL, PR, PY, QA, RO, SA, SE, SG, SI, SK, SV, SY, TF, TH, TR, TT, TW, UA, UY, VE, ZA.
  • Description du dispositif
    Medtronic MiniMed Paradigm Insulin Infusion Pumps || Model Numbers: MMT-511, MMT-512, MMT-712, MMT-712E, MMT-515, MMT-715, MMT-522, MMT-522K, MMT-722, MMT-722K, MMT-523, MMT-523K, MMT-723, MMT-723K, MMT-554, and MMT-754. || Product Usage: || Paradigm insulin infusion pumps are intended for use to deliver basal and bolus insulin to persons with diabetes.
  • Manufacturer
  • Modèle / numéro de série
    All Medfusion¿ 4000 Syringe Pumps in the field are affected by this Field Safety Corrective Action.
  • Classification du dispositif
  • Classe de dispositif
    2
  • Dispositif implanté ?
    No
  • Distribution
    Worldwide Distribution - USA (nationwide ) including the states of : AZ, NY, TN, MS, AR, WV, VA, VT, PA, DE, DC, OH, CO, NH, MI, CA, FL, CT, WA, MD, NM, RI, MA, TX, NC, IL, KY, WI and MI., and the countries of CANADA, SAUDI ARABIA and AUSTRALIA.
  • Description du dispositif
    Medfusion¿ 4000 Syringe Infusion Pumps || Medfusion¿ 4000 Syringe Infusion Pumps are designed for use in care areas for the administration of fluids requiring precisely controlled infusion rates. These pumps are indicated for use by healthcare professionals in the delivery of IV solutions, drug solutions, blood or blood products, and enteral feedings in continuous, intermittent, and body weight delivery modes.
  • Manufacturer
  • Modèle / numéro de série
  • Description du dispositif
    All Plum A+ infusion pumps:Pump    List number  Plum A+ Infusion Pump    11971  Plum A+ 3 Infusion Pump System v 10.3    12348  Plum A+ Infusion Pump v 11.3    12391  Plum A+ 3 Infusion Pump v 11.3    12618  Plum A+ 3 with Hospira MedNet Software    20678  Plum A+ Driver    20792Manufactured by Hospira Inc.
  • Manufacturer
  • Modèle / numéro de série
  • Description du dispositif
    GemStar docking station for use with specific GemStar infusion pumps. The specific products potentially affected by the two problems are shown below: Affected product (docking station list numbers) Issue Potential to occur in conjunction with products 13075-XX-07 13075-XX-09 Pump fails to power up Gemstar phase 3 pump (13000-XX, 13100-XX, 13150-XX) Error code 11/003 on pump and infusion stops Gemstar phase 4 pump (13086-XX, 13087-XX, 13088-XX) External battery pack (13073-XX) If you are unsure whether the Gemstar infusion pump is a phase 3 or a phase 4 contact Hospira for clarification. There is no corrective action in place to resolve this issue. Hospira is offering the Sapphire pump, manufactured by Q Care, on a part exchange basis to replace Gemstar pumps as detailed in Medical Device Alert MDA/2013/078 .
  • Manufacturer
263 en plus