Hollow Fiber Oxygenator

  • Modèle / numéro de série
    Lot No: 0501210038, and 0710290112.
  • Classification du dispositif
  • Classe de dispositif
    2
  • Dispositif implanté ?
    No
  • Distribution
    NC
  • Description du dispositif
    Dideco, D901 Lilliput 1, Close Phisio, Sterile EO, REF 05252, Manufacturer: Sorin Group Italia, Via Statale 12 Nord, 86, 41037 Mirandola (MO) (Italy). The product is intended for use in cardiopulmonary bypass circuits as a device to replace the function of the lungs in order to control the arterial/venous temperature and as a venous blood reservoir
  • Manufacturer
  • 1 Event

Fabricant

  • Adresse du fabricant
    Sorin Group USA, Inc., 14401 W 65th Way, Arvada CO 80004
  • Société-mère du fabricant (2017)
  • Source
    USFDA

22 dispositifs médicaux avec un nom similaire

En savoir plus sur les données ici

  • Modèle / numéro de série
    Lot: 1709190228, UDI: (01)08033178112352(17)200917(10)1709190228, Exp: 09/17/2020
  • Classification du dispositif
  • Classe de dispositif
    2
  • Dispositif implanté ?
    No
  • Distribution
    US Distribution to the states of : NJ, CA, MN, MO, MA
  • Description du dispositif
    Inspire 6 Integrated Phisio OXY w/ HVR Reservoir, Sterile EO, Catalog # 050713 || The intended uses for the two elements that constitute the oxygenator/reservoir integrated devices are: INSPIRE 6M Hollow Fiber Oxygenator: The INSPIRE 6M is intended for use in adult and small adult surgical procedures requiring cardiopulmonary bypass. It provides gas exchange support and blood temperature control. The INSPIRE 6M is intended to be used for 6 hours or less. INSPIRE HVR (Hardshell Venous/Cardiotomy Reservoir): The INSPIRE HVR is intended for use in adult and small adult surgical procedures requiring cardiopulmonary bypass. It collects, de-foams and filters venous blood and suction blood. INSPIRE HVR can be used post-operatively for chest drainage. The INSPIRE HVR is intended to be used for 6 hours or less
  • Manufacturer
  • Modèle / numéro de série
    Lot:1709190230, UDI: (01)08033178112369(17)200917(10)1709190230, Exp: 09/17/2020; Lot: 1710260210, UDI: (01)08033178112369(17)201024(10)1710260210, Exp: 10/24/2020
  • Classification du dispositif
  • Classe de dispositif
    2
  • Dispositif implanté ?
    No
  • Distribution
    US Distribution to the states of : NJ, CA, MN, MO, MA
  • Description du dispositif
    Inspire 8 Integrated Phisio OXY w/ HVR Reservoir, Sterile EO, Catalog # 050714 || The intended uses for the two elements that constitute the oxygenator/reservoir integrated devices are: INSPIRE 8M Hollow Fiber Oxygenator: The INSPIRE 8M is intended for use in adult and small adult surgical procedures requiring cardiopulmonary bypass. It provides gas exchange support and blood temperature control. The INSPIRE 8M is intended to be used for 6 hours or less. INSPIRE HVR (Hardshell Venous/Cardiotomy Reservoir): The INSPIRE HVR is intended for use in adult and small adult surgical procedures requiring cardiopulmonary bypass. It collects, de-foams and filters venous blood and suction blood. INSPIRE HVR can be used post-operatively for chest drainage. The INSPIRE HVR is intended to be used for 6 hours or less.
  • Manufacturer
  • Modèle / numéro de série
    Lot 205200
  • Classification du dispositif
  • Distribution
    Nationwide, Austria, Canada, Japan, Saudi Arabia
  • Description du dispositif
    Vision Hollow Fiber Oxygenator
  • Manufacturer
  • Modèle / numéro de série
    Various
  • Classification du dispositif
  • Classe de dispositif
    2
  • Dispositif implanté ?
    No
  • Distribution
    NY, PA, AR, IN, IL, NH, SC, NJ, MS, MI, WI, CT, CA
  • Description du dispositif
    Vision Hollow Fiber Oxygenator with GBS Coating
  • Manufacturer
  • Modèle / numéro de série
    313417, 324404, 241506, 192513, 206510, 241506, 255514, 283507, 40501, 88508, 199547, 208500, 213508, 213508A, 231517, 290542, 007515, 328426, 074507, 122554, 174519, 262552, 323419, 007515, 338420, 035504, 047500, 047501, 047502, 067549, 088507, 122555, 151543, 151542, 215501, 231519, 129535, 250502, 255515, 323419, 336410, 005504, 031514, 087515, 143509, 157511, 199513, 234518, 262511, 313451, 334412, 334412A, 038500, 045550, 053513, 102500, 129525, 160500, 193500, 216501, 252500, 276506, 283512, 241509, 255514, 122554, 047502, 328426, 074507, 125515, 157527, 290519, 199512, 133500, 130500, 241500, 314410, 328426, 213508, 313420, 024509, 004507, 067516, 348414, 101518, 047502, 314409, 323419, 007515, 045557, 059500, 109507, 154510, 046502, 143507, 067518, 101520, 038522, 348418, 038522, 080511, 129527, 206515
  • Classification du dispositif
  • Classe de dispositif
    2
  • Dispositif implanté ?
    No
  • Distribution
    Nationwide (CA, FL, IL, IN, MA, MI, MS, NH, NJ, NY, OH, PA, WI, VA), Canada, and Mexico.
  • Description du dispositif
    The GISH Vision Hollow Fiber Oxygenator with GBS coating (a non-leaching heparin coating) is a sterile, non-pyrogenic, single use, disposable, extracorporeal device designed to be used in an extracorporeal blood circuit to control exchange of gases. It is intended for the supply of oxygen to, and the removal of carbon dioxide from, the blood of humans. An integral heat exchanger is included which is intended to control the temperature of the blood.
  • Manufacturer