Baxter Healthcare Renal Div

3 dispositifs dans la base de données

  • Modèle / numéro de série
    product code S1000L3P, Serial Number 28130
  • Classification du dispositif
  • Classe de dispositif
    2
  • Dispositif implanté ?
    No
  • Distribution
    Distributed in Puerto Rico only.
  • Description du dispositif
    Baxter System 1000 Tina Single Patient Hemodialysis Delivery System; Baxter Healthcare Corporation, Renal Division, McGaw Park, IL 60085; product code S1000L3P. || Hemodialysis and Continuous Renal Replacement Therapy devices for acute and chronic hemodialysis
  • Modèle / numéro de série
    all serial numbers
  • Classification du dispositif
  • Classe de dispositif
    2
  • Dispositif implanté ?
    No
  • Distribution
    Worldwide Distribution - USA including AZ, CA, CT, DC, FL, KY, MO, NC, NM, Ny, OH, PA, TN, TX, and VA and the countries of Austria, Australia, Belgium, Brazil, Canada, Chile, China, Colombia, Denmark, Ecuador, Finland, France, Germany, Greece, Hong Kong, India, Iraq, Ireland, Israel, Italy, South Korea, Kuwait, Lebanon, Malaysia, Mexico, Netherlands, New Zealand, Norway, Oman, Panama, Peru, Philippines, Poland, Portugal, Qatar, Russia, South Africa, Saudi Arabia, Singapore, Slovania, Spain, Sweden, Switzerland, Thailand, Taiwan, Tunisia, Turkey, United Arab Emirates, United Kingom, and Venezuela.
  • Description du dispositif
    APD Disposable Sets and Extension Sets used with Baxter HomeChoice and HomeChoice PRO Automated Peritoneal Dialysis Systems; Manufactured for Baxter Healthcare Corporation, Deerfield, IL 60015 U.S.A. || The HomeChoice dialysis system is a personal cycler automated peritoneal dialysis system for pediatric and adult renal patients with fill volumes ranging from 60 mL to 3000 mL.
  • Modèle / numéro de série
    All lots of Quinton BETA-CAP Adapters, product code 8814-661001, sold by Baxter under product code 5K4560
  • Classification du dispositif
  • Classe de dispositif
    2
  • Dispositif implanté ?
    No
  • Distribution
    Class II Recall -- Nationwide Distribution
  • Description du dispositif
    Quinton BETA-CAP Adapter; a Peritoneal Dialysis accessory to the PD catheter used to connect the catheter to the PD transfer set; Covidien product code 8814-661001, Baxter product code 5K4560

2 fabricants avec un nom similaire

En savoir plus sur les données ici

  • Adresse du fabricant
    Baxter Healthcare Renal Div, 1620 Waukegan Rd Bldg R, Mc Gaw Park IL 60085-6730
  • Source
    USFDA
  • Adresse du fabricant
    Baxter Healthcare Renal Div, 1620 S Waukegan Rd, Waukegan IL 60085-6730
  • Société-mère du fabricant (2017)
  • Source