Varian brand Eclipse Release 10 with RT Chart Release 10 (Client Build 10.0.28 or Build 10.0.34), An || Eclipse Treatment Planning System used with ARIA Radiation Oncology (RT Chart || module), Reference/FSCA Identifier: CP-05277, Model Number: H48; Product is manufactured and distributed by Varian Medical Systems Inc., Palo Alto, CA. || The Eclipse Treatment Planning System (Eclipse TPS) is used to plan radiotherapy treatments for patients with malignant or benign diseases. Eclipse TPS is used to plan external beam irradiation with photon, electron and proton beams, as well as for internal irradiation (brachytherapy) treatments. In addition, the Eclipse Proton Eye algorithm is specifically indicated for planning proton treatment of neoplasms of the eye.
Worldwide distribution including the US and Internationally.
Description du dispositif
TrueBeam and TrueBeam STx, Model Number: H19, Ref/FSCA identifier: CP-06381 are intended to provide stereotactic radiosurgery and precision radiotherapy for lesions, tumors, and conditions anywhere in the body where radiation treatment is indicated.
Head Ring Posts with part number 970.280 - re-usable components of the Frame Array Module (of the Optical Guidance Platform and Floorstand devices. || Varian Medical Systems, Palo Alto, CA 94304. || The Optical Guidance Platform is for use with a charged particle accelerator to perform precise positioning of treatment for stereotactic radiosurgery or radiotherapy treatments on cranial extracranial lesions.
Varian brand GammaMed 12i Accessory: Clamping adapters for bronchial catheters, 1.8mm diameter, GammaMed 12i; Ref: BT-00264, Model 2-H63; Product is distributed by Varian Medical Systems Inc., Palo Alto, CA and Manufactured by Varian Medical Systems Haan GmbH, || Bergische Strasse 16, D-42781 Haan, Germany. || The Varian Medical System GammaMed Afterloader system is a remotely controlled intelligent robotic device intended to be used to deliver high dose-rate radiation therapy, in close proximity to and from within diseased tissues. Palliative care and treatments with curative intent to both benign and non-benign disease using interstitial, intracavitary, intraluminal, intra and inter-operative brachytherapy or combinations of any these treatment types are possible using this device.
Varian Clinac, Trilogy, Trilogy Tx and Novalis linear accelerators. || Manufactured by Varian Medical System, Palo Alto, CA. || Varian High Energy Linear Accelerator is indicated for stereotactic radiosurgery and precision radiotherapy for lesions, tumors and conditions anywhere in the body where radiation treatment is indicated.